Samsung 050JXYDEH Installation And Maintenance Manual

Samsung 050JXYDEH Installation And Maintenance Manual

With fastconnect
Air Source Heat Pump
Installation and Maintenance Manual
Model Numbers:
MIM-E03 A and B N
AE 050-090-120-140-160JXYDEH
with
Scan this code to go directly to our YouTube channel
2016 b fast connect
1
Table of Contents
loading

Summary of Contents for Samsung 050JXYDEH

  • Page 1 Air Source Heat Pump Installation and Maintenance Manual Model Numbers: MIM-E03 A and B N AE 050-090-120-140-160JXYDEH with Scan this code to go directly to our YouTube channel 2016 b fast connect...
  • Page 2: The Outdoor Unit (Boiler)

    The Outdoor Unit (boiler) Position the outdoor unit so that the air flows into an open area, where there are no plants and animals Install the outdoor unit on a flat, stable surface, the unit needs to be securely mounted at least 100mm off the ground on rubber feet. The unit must be bolted down for security using 10mm bolts and Zebedee bolts.
  • Page 3 If you want to run the system open vented you don’t need these components, the Samsung units are happy to run at anywhere from 0 – 3Bar pressure...
  • Page 4 Fast Connection kit page 1 of 4 The fast connection kit comes with all the accessories you need except a robokit and Cylinder. The idea is the fast connect kit goes on the wall inside and is pre wired, and commissioned.
  • Page 5 Fast Connect Page 2 of 4 Operation: Hot water is controlled using the Samsung cylinder sensor and controller supplied. This controller has inbuilt time clock control and includes both a daily and weekly legionella sterilisation function. The system can be either open vented or pressurised.
  • Page 6 Wiring Fast Connect with one zone heating page 3 of 4 The sparky connects the tank thermostat sensor 15m long (can’t be extended). The immersion heater to the cylinder, the thermostat or run signal input The 2 core F1F2 cable to the outdoor unit (its 10m long) and a power supply 16 Amps 2016 b fast connect...
  • Page 7 Wiring Fast Connect with multi heating zones page 3 of 4 The sparky connects the tank thermostat sensor 15m long (can’t be extended). The immersion heater to the cylinder, the thermostat or run signal input The 2 core F1F2 cable to the outdoor unit (its 10m long) and a power supply 16 Amps 2016 b fast connect...
  • Page 8 Combi hybrid with fast connection kit: The fast connect board goes outside, it’s in a waterproof enclosure, 600 high x 800 wide x 300mm deep. The fast connection kit has energy meters installed so the installer needs no other parts. Just T into the heating circuit and modify the wiring as above.
  • Page 9 Combi hybrid with fast connection kit wiring: Disconnect the stat from the boiler and wire it to the fast connect. Run a cable from fast connect to the boiler. Connect a single power supply to the fast connect board. Run a supply from fast connect to the heat pump outdoor unit Connect the pre wired comms cable to the outdoor unit.
  • Page 10: Start-Up Procedure

    Start-up Procedure: Filling and flushing, when installing any Heat pump we insist on a thorough system flush prior to connection in line with the Building Regulations for England and Wales, Part L, 2006. Using the power flusher fill the system with water and 25% Propylene Glycol, there is no pressure sensor in the unit so we can operate from open vented to 3 bar maximum.
  • Page 11: Field Settings

    Field Settings Field settings define how the unit will work, each system will have different field settings. Field settings are in groups, the 20s are for weather compensation and temperature control in heating, the 30s are for the cylinder and the 40s are for backup boilers and hybrid systems.
  • Page 12: Electrically Testing The Unit

    Electrically testing the unit: It is possible to test each component one after another using the service function. You can use this to make sure you have wired everything correctly. To access service mode press right and left button together for 6 seconds. The controller will display TEST or 7E57 press the power on/off button to start the pump, we always run the pump...
  • Page 13: Checking Flow Rate Before Starting The Heat Pump

    Checking flow rate before starting the heat pump. The flow rate through the heat pump is very high and must never fall. An alarm will show E911 if the flow falls below 17l/min on a 9 and 16Kw UNIT and 9l/min on a 5Kw unit.
  • Page 14: Starting The Unit In Heating Mode

    Starting the unit in heating mode; Press the power button (top left) AU will show meeting Automatic mode using an external run signal. Turn up your thermostats or underfloor heating to send a run signal to the unit, the pump will start immediately, a little house with a circle round it appears in the status window, the compressor in the outdoor unit starts after 3 minutes, you will see the symbol for the compressor in the status screen.
  • Page 15 Handover of the system. Leave this page with the Homeowner Thank you for buying a Samsung EHS heat pump system, your Samsung heat pump heats the house and hot water cylinder much like a normal fossil fuel boiler however there are a couple of differences which you should take notice Your installer should have provided you with a room thermostat if you have radiators or a thermostat in every room if you have under floor heating.
  • Page 16: General Advice

    General Advice: The heat pump comes with a Samsung controller which looks like this, you should not use this or press the buttons, it is used for commissioning and fault diagnosing the system only. Normally the controller will show AU or automatic mode, this means its looking for a thermostat to tell it when to run.
  • Page 17: Warranty Registration Card

    This warranty covers only the Samsung components of the installation, it is parts only with a pre-set labour allowance only. The warranty is between Freedom Heat pumps and the installation company only, this is NOT an end user warranty.
  • Page 18 I accept the terms of the Samsung warranty and confirm the system has been registered within 30 days of delivery. I also include a copy of the delivery note. Signed Name 2016 b fast connect...
  • Page 19: Maintenance Procedure

    Maintenance Monobloc Systems The Samsung heat pump should be maintained at least once a year to comply with warranty and RHI. The warranty card also doubles up as a maintenance sheet. Maintenance procedure Stop the unit, clean the strainer or magnetic filter in accordance with manufacturer’s recommendations and replace it.