Hitachi CP-AW3005 User Manual
Hide thumbs Also See for CP-AW3005:

Quick Links

Projector
CP-AX2505/CP-AX3005/CP-AX3505/CP-AW2505/CP-AW3005
User's Manual (detailed)
Operating Guide – Technical
Supported signals for COMPUTER IN
Resolution (H x V)
720 x 400
640 x 480
800 x 600
832 x 624
1024 x 768
1152 x 864
1280 x 768
1280 x 800
1280 x 1024
1366 x 768
1440 x 900
1600 x 900
*1 1400 x 1050
*2 1680 x 1050
1600 x 1200
1920 x 1080
*1) Only for CP-AX2505, CP-AX3005, CP-AX3505.
*2) Only for CP-AW2505, CP-AW3005.
Signal mode
TEXT
VGA (60Hz)
VGA (72Hz)
VGA (75Hz)
VGA (85Hz)
SVGA (56Hz)
SVGA (60Hz)
SVGA (72Hz)
SVGA (75Hz)
SVGA (85Hz)
Mac 16" mode
XGA (60Hz)
XGA (70Hz)
XGA (75Hz)
XGA (85Hz)
1152 x 864 (75Hz)
W-XGA (60Hz)
1280 x 800 (60Hz)
SXGA (60Hz)
SXGA (75Hz)
SXGA (85Hz)
WXGA (60Hz)
WXGA+ (60Hz)
WXGA++ (60Hz)
SXGA+ (60Hz)
WSXGA+ (60Hz)
UXGA (60Hz)
Full HD (60Hz)
H. frequency
(kHz)
37.9
31.5
37.9
37.5
43.3
35.2
37.9
48.1
46.9
53.7
49.7
48.4
56.5
60
68.7
67.5
47.7
49.7
64
80
91.1
47.7
55.9
60
65.2
65.3
75
67.5
1
V. frequency
Rating
(Hz)
85
VESA
59.9
VESA
72.8
VESA
75
VESA
85
VESA
56.3
VESA
60.3
VESA
72.2
VESA
75
VESA
85.1
VESA
74.5
60
VESA
70.1
VESA
75
VESA
85
VESA
75
VESA
60
VESA
60
VESA
60
VESA
75
VESA
85
VESA
59.8
VESA
59.9
VESA
60
VESA
60
VESA
60
VESA
60
VESA
60
VESA
loading

Summary of Contents for Hitachi CP-AW3005

  • Page 1 *1 1400 x 1050 SXGA+ (60Hz) 65.2 VESA *2 1680 x 1050 WSXGA+ (60Hz) 65.3 VESA 1600 x 1200 UXGA (60Hz) VESA 1920 x 1080 Full HD (60Hz) 67.5 VESA *1) Only for CP-AX2505, CP-AX3005, CP-AX3505. *2) Only for CP-AW2505, CP-AW3005.
  • Page 2 Supported signals Supported signals for HDMI Resolution (H x V) Signal mode H. frequency V. frequency Rating (kHz) (Hz) 720 x 400 TEXT 37.9 VESA 640 x 480 VGA (60Hz) 31.5 59.9 VESA VGA (72Hz) 37.9 72.8 VESA VGA (75Hz) 37.5 VESA VGA (85Hz)
  • Page 3 Supported signals NOTE...
  • Page 4: Input Menu

    Connection to the ports NOTICE COMPUTER IN1 COMPUTER IN2/MONITOR OUT INPUT menu - COMPUTER IN1, COMPUTER IN2/MONITOR OUT (1) for PC signal Signal Signal Video Red Ground Video Green (No connection) (No connection) Ground H. sync / Composite sync. Ground Red V.
  • Page 5 Connection to the ports (continued) VIDEO IN...
  • Page 6: Audio Out

    Connection to the ports (continued) HDMI1 HDMI2 10 12 14 16 18 11 13 15 17 19 Signal Signal Signal T.M.D.S. Data2 + T.M.D.S. Data0 - 16 SDA T.M.D.S. Data2 - 10 T.M.D.S. Clock + 17 DDC/CEC Ground T.M.D.S. Data1 + 12 T.M.D.S.
  • Page 7 Connection to the ports (continued) USB TYPE A USB TYPE B Signal Signal - Data - Data + Data + Data Ground Ground CONTROL 5 4 3 2 1 Signal Signal Signal (No connection) (No connection) Ground (No connection) (No connection) Signal Signal Signal...
  • Page 8 Connection to the ports (continued) To input component video signal to COMPUTER IN ports RCA plugs RCA connectors COMPONENT VIDEO OUT Disc player COMPUTER IN1 or IN2 COMPUTER IN1 and IN2 port (4).
  • Page 9 RS-232C Communication RS-232C Communication 18). Connection CONTROL OPTION menu - SERVICE - COMMUNICATION in the User's Manual - Operating Guide) RS-232C CONTROL RS-232C Cable (cross) RS-232C port CONTROL port 5 4 3 2 1 CD (1) (1) − RD(2) (2) RD TD (3) (3) TD (4) −...
  • Page 10 RS-232C Communication (continued) Communication settings 1. Protocol 2. Command format Header Data Command Header Data Setting Action Type code size code Packet Action (aH) (cH) (aH) (aH) (aH) (aH) [Header code] [Packet] [Data size] ~ 4. 5, 6, refer to (18).
  • Page 11 RS-232C Communication (continued) 3. Response code / Error code (1) ACK reply : 06h (2) NAK reply : 15h (3) Error reply : 1Ch + 0000h (4) Data reply : 1Dh + xxxxh NOTE command or data. code.
  • Page 12 Command Control via the Network (18). NOTE Connection USB TYPE A port. LAN cable (CAT-5 or greater)
  • Page 13: Communication Port

    Command Control via the Network (continued) Communication Port TCP #23 TCP #9715 Port Settings [Enable] [Network Port open Control Port1 (Port: 23)] to use TCP #23. Network Control [Enable] Port1 (Port: 23) [Authentication] is required. [Enable] [Network Control Port2 (Port: 9715)] to use TCP Port open #9715.
  • Page 14: Command Control Settings

    Command Control via the Network (continued) Command control settings [TCP #23] 1. Command format Same as RS-232C communication, refer to RS-232C Communication command format. 2. Response code / Error code (1) ACK reply : 06h Refer to RS-232C communication (11). (2) NAK reply : 15h Refer to RS-232C communication (11).
  • Page 15 Command Control via the Network (continued) 2. Response code / Error code (1) ACK reply : 06h + ××h (2) NAK reply : 15h + ××h (3) Error reply : 1Ch + 0000h + ××h (4) Data reply : 1Dh + xxxxh + ××h (5) Authentication error reply : 1Fh + 0400h + ××h (6) Projector busy reply: 1Fh + ××××h + ××h Automatic Connection Break...
  • Page 16 Network Bridge Communication 1.5 Network Bridge Function - Network Guide. NOTE Connection USB TYPE A port. CONTROL . (OPTION menu - SERVICE - COMMUNICATION in the User's Manual - Operating Guide) CONTROL RS-232C...
  • Page 17 Network Bridge Communication (continued) Communication settings menu. (OPTION menu - SERVICE - COMMUNICATION in the User's Manual - Operating Guide) Item Condition NONE/ODD/EVEN NOTE 7.4 Transmission method - Network Guide.
  • Page 18 RS-232C Communication / Network command table Command Data Names Operation Type Header Action Type Setting code Turn off 06 00 2A D3 01 00 00 60 00 00 Turn on 06 00 01 00 00 60 01 00 06 00 19 D3 02 00 00 60...
  • Page 19 RS-232C Communication / Network command table (continued) Command Data Names Operation Type Header Action Type Setting code 06 00 FD D3 02 00 04 20 00 00 CONTRAST Increment 06 00 04 00 04 20 00 00 Decrement 06 00 4A D2 05 00 04 20...
  • Page 20 RS-232C Communication / Network command table (continued) Command Data Names Operation Type Header Action Type Setting code User Gamma Execute 06 00 E0 C3 06 00 52 70 00 00 Point 3 Reset 06 00 4C FE 02 00 93 30 00 00 User Gamma Increment...
  • Page 21 RS-232C Communication / Network command table (continued) Command Data Names Operation Type Header Action Type Setting code Execute 06 00 EC C7 06 00 47 70 00 00 GAIN G Reset 06 00 8C F5 02 00 00 00 Increment 06 00 EA F5 04 00...
  • Page 22 RS-232C Communication / Network command table (continued) Command Data Names Operation Type Header Action Type Setting code 06 00 9E D0 01 00 08 20 00 00 06 00 0E D1 01 00 08 20 01 00 NATIVE 06 00 5E D7 01 00 08 20...
  • Page 23 RS-232C Communication / Network command table (continued) Command Data Names Operation Type Header Action Type Setting code AUTO 06 00 A2 70 01 00 11 22 0A 00 NTSC 06 00 C2 74 01 00 11 22 04 00 06 00 52 75 01 00 11 22...
  • Page 24 PICT.POSIT.H 06 00 D6 D4 01 00 1E 20 00 00 (CP-AW2505, 06 00 01 00 1E 20 02 00 CP-AW3005) 06 00 E5 D4 02 00 1E 20 00 00 06 00 02 00 07 20 00 00 Increment...
  • Page 25 RS-232C Communication / Network command table (continued) Command Data Names Operation Type Header Action Type Setting code 06 00 AD 8A 02 00 28 21 00 00 PERFECT FIT Increment 06 00 04 00 28 21 00 00 Decrement 06 00 05 00 28 21 00 00...
  • Page 26 RS-232C Communication / Network command table (continued) Command Data Names Operation Type Header Action Type Setting code 06 00 C7 D2 01 00 01 30 00 00 06 00 57 D3 01 00 01 30 01 00 06 00 A7 D3 01 00 01 30 02 00...
  • Page 27 RS-232C Communication / Network command table (continued) Command Data Names Operation Type Header Action Type Setting code AUDIO IN1 06 00 5E DD 01 00 34 20 01 00 AUDIO AUDIO IN2 06 00 AE DD 01 00 34 20 02 00 SOURCE - 06 00...
  • Page 28 RS-232C Communication / Network command table (continued) Command Data Names Operation Type Header Action Type Setting code 06 00 F7 D3 01 00 05 30 00 00 FRANÇAIS 06 00 67 D2 01 00 05 30 01 00 DEUTSCH 06 00 97 D2 01 00 05 30...
  • Page 29 RS-232C Communication / Network command table (continued) Command Data Names Operation Type Header Action Type Setting code MyScreen 06 00 01 00 00 30 20 00 06 00 01 00 00 30 40 00 06 00 01 00 00 30 03 00 WHITE 06 00...
  • Page 30 RS-232C Communication / Network command table (continued) Command Data Command Data Names Names Operation Type Operation Type Header Header Action Action Type Type Setting code Setting code 06 00 D2 62 01 00 02 37 01 00 06 00 22 62 01 00 02 37 02 00...
  • Page 31 RS-232C Communication / Network command table (continued) Command Data Names Operation Type Header Action Type Setting code COMPUTER IN1 06 00 C6 32 01 00 01 36 00 00 COMPUTER IN2 06 00 06 30 01 00 01 36 04 00 06 00 F6 35 01 00...
  • Page 32 RS-232C Communication / Network command table (continued) Command Data Names Operation Type Header Action Type Setting code 06 00 3A C3 01 00 00 35 00 00 IMAGE-1 06 00 AA C2 01 00 00 35 01 00 IMAGE-2 06 00 5A C2 01 00 00 35...
  • Page 33 PJLink command Commands Control Description Parameter or Response POWR POWR ? INPT Input Source selection INPT ? Input Source inquiry AVMT AV Mute AVMT ? AV Mute inquiry (continued on next page)
  • Page 34 Parameter or Response ERST ? Error Status inquiry Error INST ? 11 12 23 31 33 41 51 52 NAME ? HITACHI INF1 ? inquiry CP-AX2505 CP-AX3005 INF2 ? Model Name inquiry CP-AX3505 CP-AW2505 CP-AW3005 INFO ? Class Information inquiry 1 NOTE...

This manual is also suitable for:

Cp-aw2505Cp-ax3505Cp-ax2505Cp-ax3005