Fujitsu AS*G09LTCA Design & Technical Manual

Wall mounted type

Quick Links

AIR CONDITIONER

Wall Mounted type

DESIGN & TECHNICAL MANUAL
INDOOR
OUTDOOR
AS  G09LTCA
AS  G12LTCA
AO  G09LTC
AO  G12LTC
Table of Contents
loading

Summary of Contents for Fujitsu AS*G09LTCA

  • Page 1: Wall Mounted Type

    AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS  G09LTCA AS  G12LTCA OUTDOOR AO  G09LTC AO  G12LTC...
  • Page 2: Indoor Unit

    1. INDOOR UNIT WALL MOUNTED TYPE : ASG09LTCA ASG12LTCA DTR_AS054E_03 2011.11.14...
  • Page 3: Table Of Contents

    CONTENTS 1. INDOOR UNIT 1. FEATURE ........................01 - 01 2. WIRELESS REMOTE CONTROLLER ..........01 - 03 3. SPECIFICATIONS ....................01 - 05 4. DIMENSIONS ......................01 - 06 5. WIRING DIAGRAMS ..................01 - 08 6. CAPACITY TABLE ....................
  • Page 4: Feature

    FEATURE MODEL „ „ ASG09LTCA / AOG09LTC ASG12LTCA / AOG12LTC AO  G09LTC AO  G12LTC FEATURES „ „ Energy-Efficiency classification A „ Europe Energy-Efficiency classification A achieved Thin & Slim design „ Thin and slim design is realized by Ø5mm heat Big open panel and High density multi path heat exchanger and high efficiency wind blower.
  • Page 5: Economy Operation

    Energy saving control „ Human sensor catches movements of people in a room, and operates with lower capacity when the room is empty. When people come back to the room, it automatically returns to previous operating mode. Energy saving operation by detecting someone’s movement Human sensor 10°C HEAT Operation...
  • Page 6: Wireless Remote Controller

    WIRELESS REMOTE CONTROLLER FEATURES „ „ 3 Mode timer setup  „ (Weekly / Program / Sleep) are possible. Easy operation.  „ Easy to change signal code (4 patterns) by button operation.  „ Simple function setting „ Setting of the air conditioner selection function is performed by remote controller. Built-in timers „...
  • Page 7 FUNCTIONS „ „ SENSOR button Signal Transmitter MODE button FAN button 10 °C HEAT button ECONOMY button SWING button TEMP. button OUTDOOR UNIT SET button LOW NOISE button POWERFUL button WEEKLY button TIMER SETTING button START/STOP ON/OFF button button SEND button SLEEP button SELECT button RESET button...
  • Page 8: Specifications

    SPECIFICATIONS WALL MOUNTED Type INVERTER HEAT PUMP Model name AS  G09LTCA AS  G12LTCA Power source 230V~ 50Hz Available voltage range 198-264V~ 50Hz Cooling European energy label Heating 2.50 3.50 Rated Btu/h 8,500 11,900 Cooling 0.9-3.5 1.1-4.0 Min-Max Btu/h 3,100-11,900 3,800-13,600 Capacity...
  • Page 9: Dimensions

    DIMENSIONS MODEL : ASG09LT, ASG12LT „ „ (Unit : mm) 187: Installed state - (01 - 06) -...
  • Page 10 INSTALLATION PLACE „ „ (Unit : mm) - (01 - 07) -...
  • Page 11: Wiring Diagrams

    WIRING DIAGRAMS MODEL : ASG09LT, ASG12LT „ „ - (01 - 08) -...
  • Page 12: Capacity Table

    CAPACITY TABLE 6-1. COOLING CAPACITY MODEL : ASG09LT „ „ 13.3 Indoor temperature °CDB °CWB °CDB 2.34 1.62 0.35 2.61 1.63 0.36 2.70 1.77 0.36 2.87 1.78 0.37 2.96 1.92 0.37 3.14 1.91 0.37 3.32 2.04 0.37 2.22 1.54 0.40 2.48 1.55 0.40...
  • Page 13: Heating Capacity

    6-2. HEATING CAPACITY MODEL : ASG09LT „ „ 13.3 Indoor temperature (°CDB) (°CDB) (°CWB) 3.35 1.24 3.27 1.26 3.19 1.29 3.11 1.32 3.03 1.34 3.74 1.31 3.65 1.34 3.56 1.37 3.47 1.39 3.38 1.42 4.03 1.40 3.93 1.43 3.84 1.46 3.74 1.49 3.64...
  • Page 14: Fan Performance

    FAN PERFORMANCE 7-1. AIR VELOCITY DISTRIBUTION Note: Fan speed : High MODEL : ASG09LT „ „ Operation mode : FAN Unit : m/s TOP VIEW Vertical flap : Up Horizontal flap : Center Unit : m/s TOP VIEW Vertical flap : Up Horizontal flap : Right &...
  • Page 15 Note: Fan speed : High MODEL : ASG12LT „ „ Operation mode : FAN Unit : m/s TOP VIEW Vertical flap : Up Horizontal flap : Center Unit : m/s TOP VIEW Vertical flap : Up Horizontal flap : Right & Left Unit : m/s SIDE VIEW Vertical flap : Up...
  • Page 16: Air Flow

    7-2. AIR FLOW MODEL : ASG09LT „ „ Cooling „ Number of Fan speed rotations Air flow (r.p.m.) HIGH 1300 1080 QUIET Heating „ Number of Fan speed rotations Air flow (r.p.m.) HIGH 1300 1120 QUIET - (01 - 13) -...
  • Page 17 MODEL : ASG12LT „ „ Cooling „ Number of Fan speed rotations Air flow (r.p.m.) HIGH 1370 1120 QUIET Heating „ Number of Fan speed rotations Air flow (r.p.m.) HIGH 1370 1180 QUIET - (01 - 14) -...
  • Page 18: Operation Noise

    OPERATION NOISE 8-1. NOISE LEVEL CURVE MODEL : ASG09LT „ „ Cooling Heating „ „ NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 High NC-45 NC-45 High NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 NC-20 NC-20 Quiet Quiet NC-15 NC-15 1,000 2,000...
  • Page 19: Sound Level Check Point

    8-2. SOUND LEVEL CHECK POINT - (01 - 16) -...
  • Page 20: Electric Characteristics

    ELECTRIC CHARACTERISTICS Model name ASG09LT ASG12LT Voltage 230~ Power supply Frequency Max. operating current Connection cable 1.0-1.5 *1)Wiring Spec. Limited wiring length *1) Wiring Spec. Selected Sample (Selected based on Japan Electrotechnical Standard and Codes Committee E0005) - (01 - 17) -...
  • Page 21: Safety Devices

    SAFETY DEVICES Model Protection form ASG09LT ASG12LT Circuit protection Current fuse (PCB) 3.15A 250V Terminal protection Current (thermal) fuse 3A 250V °C OFF Fan motor protection Thermal protector program °C ON - (01 - 18) -...
  • Page 22: External Input & Output

    EXTERNAL INPUT & OUTPUT Connector INPUT OUTPUT REMARKS CNA01 Control input See external CNB01 Operation status output input/output settings for details. CNB02 Error status output 11-1. EXTERNAL INPUT CONTROL INPUT (Operation/Stop or Forced stop) „ „ The air conditioner can be remotely operated by means of the following on-site work. "Operation/Stop"...
  • Page 23 When function setting is "Forced stop" mode „ Input signal Forced stop Command Normal Operation Indoor unit Stop Remote controller Remote control operation invalidity Parts (Optional) „ Parts name Model name External connect kit UTY-XWZXZ5 Communication kit UTY-TWBXF * For operating the EXTERNAL function, the Compact wall mounted type requires the communication kit in addition to the wire (UTY-XWZXZ5).
  • Page 24: External Output

    11-2. EXTERNAL OUTPUT OPERATION STATUS OUTPUT „ „ An air conditioner operation status signal can be output. Circuit diagram example „ Indoor control PC board Communication kit Connected unit Connector 24V DC Ex.)Relay unit Ex.)Display Relay power supply *10 m Signal Optional parts Field supply...
  • Page 25 ERROR STATUS OUTPUT „ „ An air conditioner error status signal can be output. Circuit diagram example „ Indoor control PC board Communication kit Connected unit Connector 24V DC Ex.)Relay unit Ex.)Display Relay power supply *10 m Signal Optional parts Field supply * Make the distance from the PC board to the connected unit within 10m.
  • Page 26: Function Setting

    FUNCTION SETTING 12-1. INDOOR UNIT (Setting by remote controller) • The function settings of the control of the indoor unit can be changed by this procedure according to the installation conditions. Incorrect settings can cause the indoor unit malfunction. • After the power is turned on, perform the “FUNCTION SETTING”...
  • Page 27: Function Details

    FUNCTION DETAILS „ „ Compact wall Functions mounted 1) Filter sign 2) Cooler room temperature correction 3) Heater room temperature correction 4) Auto restart Indoor room temperature sensor switching function 6) Remote controller signal code 7) External input control 1) Filter sign The indoor unit has a sign to inform the user that it is time to clean the filter.
  • Page 28 4) Auto restart Enable or disable automatic system restart after a power outage. (  ... Factory setting) Setting description Function number Setting value  * Auto restart is an emergency function such as for power failure etc. Do not start and stop the indoor unit by this function in normal operation. Be sure to operate by the control unit, or external input device.
  • Page 29 REMOTE CONTROLLER SIGNAL CODE SETTING „ „ Use the following steps to select the signal code of the remote controller. (Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code.) (1) Press the START/STOP ( / ) button until only the clock is displayed on the remote controller display.
  • Page 30: Optional Parts

    OPTIONAL PARTS Exterior Parts name Model No. Summary Unit control is performed by Wired remote wired remote controller. UTY-RNNYM controller *Optional communication kit is necessary for the installation. Unit control is performed by Simple remote simple remote controller. UTY-RSNYM controller *Optional communication kit is necessary for the installation.
  • Page 31 2. OUTDOOR UNIT SINGLE TYPE : AOG09LTC AOG12LTC DTR_AO086E_01 2011.04.08...
  • Page 32 CONTENTS 2. OUTDOOR UNIT 1. SPECIFICATIONS ....................02 - 01 2. DIMENSIONS ......................02 - 02 3. REFRIGERANT CIRCUIT ................02 - 04 4. WIRING DIAGRAMS ..................02 - 05 5. CAPACITY COMPENSATION RATE FOR PIPE LENGTH AND HEIGHT DIFFERENCE ..................
  • Page 33: Specifications

    SPECIFICATIONS Type INVERTER HEAT PUMP Model name AO  G09LTC AO  G12LTC Power sourse 230V ~ 50Hz Available voltage range 198-264V ~ 50Hz Starting current Cooling 1,700 2,050 Airflow rate Heating 1,700 2,000 Type×Q'ty Propeller fan×1 Motor output Cooling Sound pressure level dB(A) Heating...
  • Page 34: Dimensions

    DIMENSIONS MODEL : AOG09LT „ „ (Unit : mm) Top view Front view Side view Air flow Drain pipe 4-ø11.3mm hole mounting place (ø20) Bottom view INSTALLATION PLACE „ „ When there are obstacles at When there are obstacles at When there are obstacles at the the back or front sides.
  • Page 35 MODEL : AOG12LT „ „ (Unit : mm) Top view Side view Front view Air flow Drain pipe 4-Ø11.3mm hole mounting place (Ø20) Bottom view INSTALLATION PLACE „ „ When there are obstacles at When there are obstacles at When there are obstacles at the the back or front sides.
  • Page 36: Refrigerant Circuit

    REFRIGERANT CIRCUIT MODEL : AOG09LT, AOG12LT „ „ Heat exchanger 3-Way ( INDOOR ) valve 2-Way valve Muffler 4-Way valve Strainer Expansion valve Heat exchanger Strainer ( OUTDOOR ) Cooling Heating Refrigerant pipe diameter Liquid : 1/4" (6.35 mm) Gas : 3/8" (9.52 mm) - (02 - 04) -...
  • Page 37: Wiring Diagrams

    WIRING DIAGRAMS MODEL : AOG09LT „ „ - (02 - 05) -...
  • Page 38 MODEL : AOG12LT „ „ - (02 - 06) -...
  • Page 39: Capacity Compensation Rate For Pipe Length And Height Difference

    CAPACITY COMPENSATION RATE FOR PIPE LENGTH AND HEIGHT DIFFERENCE MODEL : AOG09LT „ „ Pipe length (m) COOLING 0.858 0.868 Û 1 0.929 0.872 0.882 Indoor unit is upper than 0.960 0.933 0.876 0.885 outdoor unit. 0.992 0.964 0.937 0.879 0.889 Height difference H...
  • Page 40 MODEL : AOG12LT „ „ Pipe length (m) COOLING 0.893 0.909 Û 1 0.955 0.908 0.924 Indoor unit is upper than 0.975 0.959 0.912 0.928 outdoor unit. 0.992 0.979 0.963 0.916 0.931 Height difference H 1.000 0.987 0.970 0.923 0.939 1.000 0.987 0.970...
  • Page 41: Additional Charge Calculation

    ADDITIONAL CHARGE CALCULATION MODEL : AOG09LT „ „ Refrigerant type R410A Refrigerant amount 1050 Refrigerant charge „ Total pipe length 15 or less 20 (MAX) 20g/m Additional charge MODEL : AOG12LT „ „ Refrigerant type R410A Refrigerant amount 1200 Refrigerant charge „...
  • Page 42: Air Flow

    AIR FLOW MODEL : AOG09LT „ „ Cooling „ Number of rotations Air flow (r.p.m.) 1700 1000 Heating „ Number of rotations Air flow (r.p.m.) 1700 1000 MODEL : AOG12LT „ „ Cooling „ Number of rotations Air flow (r.p.m.) 2050 1206 Heating...
  • Page 43: Operation Noise

    OPERATION NOISE 8-1. NOISE LEVEL CURVE MODEL : AOG09LT „ „ Cooling Heating „ „ NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 NC-45 NC-45 NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 NC-20 NC-20 NC-15 NC-15 1,000 2,000 4,000 8,000 1,000 2,000...
  • Page 44: Sound Level Check Point

    8-2. SOUND LEVEL CHECK POINT - (02 - 12) -...
  • Page 45: Electric Characteristics

    ELECTRIC CHARACTERISTICS Model name AO  G09LT AO  G12LT Voltage 230 ~ Power supply Frequency *1) Max operating current 10.5 Starting Current Main Fuse (Circuit breaker) Current *2) Wiring Spec.: Power Cable *3) Limited wiring length : *1) The maximum current is the total current of indoor unit and outdoor unit. *2) Wiring Spec.: Selected Sample (Selected based on Japan Electrotechnical Standard and Codes Committee E0005)
  • Page 46: Safety Devices

    SAFETY DEVICES Model Protection form AO  G09LT AO  G12LT Current fuse 20A/250V Circuit protection (MAIN PRINTED 5A/250V CIRCUIT BOARD) Thermal protection OFF : 100 °C Fan motor protection program ON : 95 °C Terminal protection program OFF:110°C High Pressure Protection COMPRESSOR TEMP.