AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LECA AS G14LECA AS G09LECA AS G12LECA OUTDOOR AO G07LEC AO G14LEC AO G09LEC AO G12LEC...
Page 2
1. INDOOR UNIT WALL MOUNTED TYPE : ASG07LECA ASG09LECA ASG12LECA ASG14LECA DTR_AS049E_03 2011.03.23...
FEATURE MODEL ASG07LECA / AOG07LEC ASG09LECA / AOG09LEC ASG12LECA / AOG12LEC AS G07LECA AS G14LECA ASG14LECA / AOG14LEC AS G09LECA AS G12LECA AO G07LEC AO G14LEC AO G09LEC FEATURES AO G12LEC ...
10°C HEAT Operation The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied Caution) • When the room temperature is higher than 10°C, “10°C HEAT” operation does not start. Operation starts and maintains the room temperature at 10°C when the temperature drops below 10°C.
Page 6
Air conditioner filter features Dirty Air Ion Deodorization Filter Apple-catechin Filter Clean Air Long-life Ion Apple- Deodorization Filter catechin Filter Easy maintenance Easy maintenance and always clean. Troublesome maintenance has been made easy. Since the front panel is easy to remove, maintenance is also easy. - (01 - 03) -...
WIRELESS REMOTE CONTROLLER FEATURES Four kinds of timer setup (On / Off / Program / Sleep) are possible. Four kinds of timers. Easy operation. Easy to change transmission code (4 patterns) by button operation. ...
Page 8
FUNCTIONS Signal Transmitter 10 °C HEAT button MODE button ECONOMY button OUTDOOR UNIT LOW NOISE button ON TIMER button OFF TIMER button CLOCK ADJUST button POWERFUL button SET TEMP. button ( START/STOP button FAN button SWING button SET button SLEEP TIMER button CANCEL button RESET button...
SPECIFICATIONS WALL MOUNTED Type INVERTER HEAT PUMP Model name AS G07LECA AS G09LECA AS G12LECA AS G14LECA Power source 230V~ 50Hz Available voltage range 198-264V~ 50Hz Cooling European energy label Heating 2.10 2.50 3.40 4.00 Rated BTU/h 7,200 8,500...
FAN PERFORMANCE 7-1. AIR VELOCITY DISTRIBUTION Note: Fan speed : High MODEL : ASG07LE, ASG09LE, ASG12LE Operation mode : FAN Unit : m/s TOP VIEW Vertical flap : Up Horizontal flap : Center Unit : m/s TOP VIEW Vertical flap : Up Horizontal flap : Right &...
Page 17
Note: Fan speed : High MODEL : ASG14LE Operation mode : FAN Unit : m/s TOP VIEW VERTICAL FLAP : Upward HORIZONTAL FLAP : Center Unit : m/s TOP VIEW VERTICAL FLAP : Upward HORIZONTAL FLAP : Right & Left Unit : m/s SIDE VIEW VERTICAL FLAP : Upward...
7-2. AIR FLOW MODEL : ASG07LE, ASG09LE, ASG12LE Cooling Number of Fan speed rotations Air flow (r.p.m.) HIGH 1400 1200 QUIET Heating Number of Fan speed rotations Air flow (r.p.m.) HIGH 1440 1200 QUIET - (01 - 15) -...
Page 19
MODEL : ASG14LE Cooling Number of Fan speed rotations Air flow (r.p.m.) HIGH 1400 1230 1000 QUIET Heating Number of Fan speed rotations Air flow (r.p.m.) HIGH 1400 1230 1050 QUIET - (01 - 16) -...
ELECTRIC CHARACTERISTICS Model name ASG07LE ASG09LE ASG12LE ASG14LE Voltage 230~ Power supply Frequency Max. operating current Connection cable 1.0-1.5 *1)Wiring Spec. Limited wiring length *1) Wiring Spec. Selected Sample (Selected based on Japan Electrotechnical Standard and Codes Committee E0005) - (01 - 20) -...
SAFETY DEVICES Model ASG07LE Protection form ASG09LE ASG12LE ASG14LE Circuit protection Current fuse (PCB) 3.15A 250V Terminal protection Current (thermal) fuse 3A 250V °C OFF Fan motor protection Thermal protector program °C ON - (01 - 21) -...
EXTERNAL INPUT & OUTPUT Connector INPUT OUTPUT REMARKS CN303 Control input See external input/output settings CN304 Operation status output for details. 11-1. EXTERNAL INPUT CONTROL INPUT (Operation/Stop or Forced stop) The air conditioner can be remotely operated by means of the following on-site work. "Operation/Stop"...
Page 26
When function setting is "Forced stop" mode Input signal Forced stop Command Normal Operation Indoor unit Stop Remote controller Remote control operation invalidity Parts (Optional) Parts name Model name External connect kit UTY-XWZX UTY-XCBXE (for AS G07/09/12LE) Communication box kit UTY-XCBXZ1 (for AS ...
11-2. EXTERNAL OUTPUT OPERATION STATUS OUTPUT An air conditioner operation status signal can be output. Circuit diagram example Indoor control PC board Communication kit Connected unit Connector 24V DC Ex.)Relay unit Ex.)Display Relay power supply *10 m Signal Optional parts Field supply...
FUNCTION SETTING 12-1. INDOOR UNIT (Setting by remote controller) • The function settings of the control of the indoor unit can be changed by this procedure according to the installation conditions. Incorrect settings can cause the indoor unit malfunction. • After the power is turned on, perform the “FUNCTION SETTING”...
FUNCTION DETAILS Compact wall Functions mounted 1) Filter sign 2) Cooler room temperature correction 3) Heater room temperature correction 4) Auto restart Indoor room temperature sensor switching function 6) Remote controller signal code 7) External input control 1) Filter sign The indoor unit has a sign to inform the user that it is time to clean the filter.
Page 30
4) Auto restart Enable or disable automatic system restart after a power outage. ( ... Factory setting) Setting description Function number Setting value * Auto restart is an emergency function such as for power failure etc. Do not start and stop the indoor unit by this function in normal operation. Be sure to operate by the control unit, or external input device.
Page 31
REMOTE CONTROLLER SIGNAL CODE SETTING Use the following steps to select the signal code of the remote controller. (Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code.) Press the START/STOP button until only the clock is displayed on the remote controller display.
OPTIONAL PARTS Exterior Parts name Model No. Summary Unit control is performed by Wired remote wired remote controller. UTY-RNNYM controller *Optional communication kit is necessary for the installation. Unit control is performed by Simple remote simple remote controller. UTY-RSNYM controller *Optional communication kit is necessary for the installation.
SPECIFICATIONS Type INVERTER HEAT PUMP Model name AO G07LEC AO G09LEC AO G12LEC AO G14LEC Power sourse 230V~ 50Hz Available voltage range 198-264V ~ 50Hz Starting current Cooling 1,720 1,830 1,800 Airflow rate Heating 1,510 1,600 1,660 Type×Q'ty Propeller fan×1...
DIMENSIONS MODEL : AOG07LE, AOG09LE, AOG12LE (Unit : mm) INSTALLATION PLACE When there are obstacles at When there are obstacles at When there are obstacles at the the back or front sides. the back, side(s), and top. back, side with the installation of more than one unit.
Page 37
MODEL : AOG14LE (Unit : mm) INSTALLATION PLACE When there are obstacles at When there are obstacles at When there are obstacles at the the back or front sides. the back, side(s), and top. back, side with the installation of more than one unit.
AIR FLOW MODEL : AOG07LE, AOG09LE Cooling Number of rotations Air flow (r.p.m.) 1720 1011 Heating Number of rotations Air flow (r.p.m.) 1510 MODEL : AOG12LE Cooling Number of rotations Air flow (r.p.m.) 1830 1076 Heating...
Page 46
MODEL : AOG14LE Cooling Number of rotations Air flow (r.p.m.) 1800 1058 Heating Number of rotations Air flow (r.p.m.) 1660 - (02 - 12) -...
ELECTRIC CHARACTERISTICS Model name AO G07LE AO G09LE AO G12LE AO G14LE Voltage 230 ~ Power supply Frequency *1) Max operating current 10.5 Starting Current Main Fuse (Circuit breaker) Current *2) Wiring Spec.: Power Cable *3) Limited wiring length : *1) The maximum current is the total current of indoor unit and outdoor unit.
SAFETY DEVICES Model Protection form AO G07LE AO G09LE AO G12LE AO G14LE Current fuse 20A/250V Circuit protection (MAIN PRINTED 5A/250V CIRCUIT BOARD) Thermal protection OFF : 100 °C Fan motor protection program ON : 95 °C Terminal protection program OFF:110°C...