Motorola PTP 300 Deployment Manual

Motorola PTP 300 Deployment Manual

Motorola network router user manual
Hide thumbs Also See for PTP 300:

Quick Links

PTP 300/500 Series
Deployment Guide
Contents
Protect Your Installation ....................................................................2
Checklist, Site Survey and Tools ......................................................4
Hoist & Safety Loop...........................................................................7
Mast Installation Instructions .............................................................8
Wiring Diagram..................................................................................9
Recommended Cable Specification ................................................10
Cable and Gland Installation Notes .................................................12
Pre-Power Testing ...........................................................................13
Post-Power Testing and Fault Finding.............................................15
Installation and Commissioning.......................................................16
Registration Warranty and Ordering Information.............................19
License Keys and Regulatory Information.......................................20
Table of Contents
loading

Summary of Contents for Motorola PTP 300

  • Page 1: Table Of Contents

    PTP 300/500 Series Deployment Guide Contents Protect Your Installation ...2 Checklist, Site Survey and Tools ...4 Bench Test and Configuration - Pre and Post-Power Checks ...5 Bench Test and Configuration - Configuration Checks...6 Hoist & Safety Loop...7 Mast Installation Instructions ...8 Wiring Diagram...9...
  • Page 2: Protect Your Installation

    We recommend that the practices and procedures detailed in the Motorola manual R56 "STANDARDS AND GUIDELINES FOR COMMUNICATION SITES" (68P81089E50) be applied to all new site build activities. For a copy on the manual please see your local Motorola representative. The manual can be downloaded from the Motorola Intranet site http://compass.mot.com/go/190860869...
  • Page 3 Protect Your Installation Recommended Recommended Zone A Zone A Zone B Zone B • Zone A – A direct strike is possible, mounting the ODU in this zone is not recom- mended. • Zone B –Indirect EMD (Lightning) effects are still possible, however, mounting within Zone B significantly reduces the possibility of a direct strike For further explanation and connection details see User Guide section - Lightning Protection Antenna Cable...
  • Page 4: Checklist, Site Survey And Tools

    Checklist, Site Survey and Tools Before performing an installation of a Motorola PTP 300 or a PTP 500 Series sys- tem, ensure that you have read this entire guide and taken note of any safety in- formation contained. Checklist •...
  • Page 5: Bench Test And Configuration - Pre And Post-Power Checks

    Bench Testing (Optional) - Connect and Power Up It is advised that the link be configured and tested on a bench before the final installation of the units on a pole or a mast. The following steps give details of how to connect an ODU to a PC in order to check the configuration details, change the IP settings or modify the license key.
  • Page 6: Bench Test And Configuration - Configuration Checks

    Step 11: You may wish to upgrade the software. If so, select ‘Software Upgrade’ and follow the on-screen instruction. Latest software is available from our web site: (http://motorola.motowi4solutions.com/software/#ptp) Step 12: Check the License Key informa- tion and ensure you are using the correct Region Code.
  • Page 7: Hoist & Safety Loop

    Use the integral safety loop for hoisting the ODU up a mast or building. When the ODU is in position, use the safety loop as a fixing point to secure a permanent lanyard from the tower/ building to the ODU, as a precaution against mounting failure. Warning! The safety lanyard must not exceed 1 m (approx 3 ft) in length.
  • Page 8: Mast Installation Instructions

    Mast Installation Instructions Earth bonding lead Attach free end (large tag M10) to Tower Metal work – NB On no ac- count must this be at- tached to the mount- ing bracket bolts!! Step 1: Your equipment will already have the mounting bracket fitted.
  • Page 9: Wiring Diagram

    Motorola PTP 300/500 Series Installation Wiring Lightning protection built into PTP xx500 or PTP xx300 Note the numbering of the pins in this diagram.
  • Page 10: Recommended Cable Specification

    Correct cable preparation for the recommended cable Caution! Check that the correct crimp tool is being used for the RJ45 con- nector utilized.
  • Page 11 Foil trimmed back to here Cable Type; CommScope 2003OD Connector Type; Tyco (AMP), 336330-1 Crimp Tool; Tyco (AMP), 790163-1 (Includes die set) Gland; Motorola WB1811 8 Brown 7 Brown/White 6 Green 5 Blue/White 4 Blue 3 Green/White 2 Orange 1 Orange/White...
  • Page 12: Cable And Gland Installation Notes

    Cable and Gland Installation Notes Step 1: Make a cable as specified on Page 10 or 11. Plug in the RJ 45 into the ODU. Step 3: Once the gland is fully hand screwed into the ODU it may be tight- ened to a torque of to 7 ftlbs/10Nm, with a 22mm wrench.
  • Page 13: Pre-Power Testing

    Before plugging the RJ45 connector fitted to the lower LPU (or if not fitted the ODU) into the PIDU check the following resistances at the RJ45; Check the cable resistance between pins 1&2, 3&6, 4&5 and 7&8 at the RJ45. Check against column 2 in Table 1.
  • Page 14: Pre-Power Testing - Recording Resistance Values

    Pre-Power Testing - Recording Resistance Values Record the information listed in Table 2. This information will be useful if there is a need to contact Motorola Support or to identify future changes in the installation. Measure Measured Resistance Resistance Between Pins...
  • Page 15: Post-Power Testing And Fault Finding

    Post-Power Testing and Fault Finding The correct operation is as follows Connect the RJ45 to the PIDU Plus and apply power to the PIDU Plus, the green power LED should illuminate continuously. 30 seconds after powering, the orange Ethernet LED should be observed starting with 10 slow flashes.
  • Page 16: Installation And Commissioning

    LINKPlanner and that a new report has been printed. The Motorola PTP 300 and PTP 500 Series use audible tones to assist the installer with ODU alignment. The pitch (frequency) of the tone is relative to the received signal strength. The higher the received signal strength the higher the frequency of the tone emitted.
  • Page 17 • PTP 300 and PTP 500 Series do not require the user to enter the link range. The Master unit typically takes less than 60 seconds to determine the length of the link being installed. The Master unit will remain in the Scanning state until the length of the link has been established.
  • Page 18 The LINKPlanner may need re-running to account for new known obstacles any time during the operation of the link. Note that for short ranges and for links installed when Radar is Enabled, the PTP 300 and PTP 500 Series software will adjust automatically the maximum Transmit Power when the unit is disarmed.
  • Page 19: Registration Warranty And Ordering Information

    Registration Warranty and Ordering Information The PTP 300 and the PTP 500 are each an extraordinarily robust radio communications link with unsurpassed availability and reliability. Along with your Motorola PTP Bridge you get a 12- month Standard Warranty that provides a 30-day repair-and-replacement program for hard- ware defect failures and minor software enhancements as they become available.
  • Page 20: License Keys And Regulatory Information

    MOTOROLA, the stylized M Logo and all other trademarks indicated as such herein are trademarks of Motorola, Inc. ® Reg. US Pat & Tm. Office. All other product or service names are the property of their respective owners. © 2006-2008 Motorola, Inc. All rights reserved.

This manual is also suitable for:

Ptp 500

Table of Contents