GE 15042 Manual
Hide thumbs Also See for 15042:
Available languages

Available languages

Quick Links

Digital Timer
Install Set Up:
1. If the time screen is completely blank it will need to be plugged into an outlet before
programming can begin. If the screen is displaying numbers, it can be programmed
and plugged into the wall afterwards.
2. Before programming, all settings should be reset. The reset button is located just
below the "HOUR" button and is identified by "RESET". Use a paper clip or ball point
pen to push the "RESET" button. Once pushed the screen will show the display below
on the screen. See Diagram A
Diagram A
After few seconds
Current Time Setting:
1. Keep the "CLOCK" button pressed during the entire setting operation.
2. Press the "HOUR" button to set the hours.
3. Press the "MIN" button to set the minutes.
4. Press the "DAY" button to select the correct day of the week.
5. Release the "CLOCK" button. The time will now be set!
Programming the On/Off Times:
1. Press the "SET" button once. Diagram B should appear.
2. 1 ON --:-- Should be the first setting.
There are a total of 20 On/Off settings. Diagram B
Diagram B
Diagram C
3. Press the "HOUR" and MIN" buttons to set the ON time.
4. Press the "DAY" button to select the day(s) that this setting is relevant.
5. Press the "SET" button to save and proceed to the 1 OFF --:-- screen. Diagram C
6. Repeat steps 1 through 5 to set ON/OFF times. Pressing the "SET" button again will
take you through the other 19 ON/OFF settings.
*Timer must be in the "Auto On" or "Auto Off" mode to work. See "Switching Mode
Indication" section.
Multiple Weekday Switching Groups:
Apart from individual week days, pressing the "DAY" button also selects multiple day
combinations such as:
• Monday thru Friday
• Tuesday & Thursday & Saturday
• Saturday & Sunday
• Monday thru Wednesday
• Monday thru Saturday
• Thursday thru Saturday
• Monday & Wednesday & Friday
• Monday thru Sunday
After selecting a particular day combination, the ON/OFF selection will be in effect on the
day configuration selected from above.
Reset Button:
1. Press the "SET" button to select the ON/OFF setting that needs to be changed
" button to reset the current ON/OFF setting seen in Diagram D
2. Press the "
without having to scroll through all the hours.
Diagram D
Current time display
Switching Mode Indication:
The actual mode is shown in the display as "ON", "AUTO ON", "OFF" or "AUTO OFF" together
with the time of day. Use the "MANUAL" button to adjust to the desired setting. This can
be used to override the timer as explained in the "Manual Override Option" section.
Manual Override Option:
Independent of the programming, it is possible at any given time to advance to the next
switching command by continuously pressing the key "MANUAL" ,as shown below:
AUTO OFF
ON
AUTO ON
ON = Always ON;
OFF = Always OFF;
AUTO ON = Timer is ON and ON/OFF program is activated.
AUTO OFF = Timer is OFF and ON/OFF program is activated.
See GE Timers and manuals
http://waterheatertimer.org/GE-timers-and-manuals.html
OFF
Programming the Countdown Feature:
1. Press the "SET" button repeatedly until the CTD icon appears on the display. This will
appear after the ON/OFF program; refer to Diagram E
2. Press the "HOUR", "MIN" buttons to set the amount of time desired for the device to be
on before turning off.
3. Press the "CLOCK" button to store the setting and return to the main display.
Diagram E
Activating the Countdown Feature:
1. Press the "HOUR" and "MIN" button simultaneously to activate the countdown feature.
Refer to Diagram F for more details
2. Other Features of the Countdown
a. Press the "MANUAL" button to pause or continue the countdown.
b. Press the "CLOCK" button to switch between the clock and countdown display.
c. Press "HOUR" and "MIN" button simultaneously to deactivate the countdown.
Diagram F
HOUR
+
MIN
Current Time Display
MANUAL
Countdown Pause
Random, ON/OFF Setting:
Random is a feature that will randomize your current settings either + or - 30 minutes,
giving your home a lived in appearance to deter intruders.
1. Press and hold the "HOUR" button for 3 seconds to activate the random feature. The
display will show the RND icon. See Diagram G.
2. Press and hold the "HOUR" button for 3 seconds to deactivate the random feature. The
RND icon will disappear from the screen.
Diagram G
Hour
Daylight Saving Time (DST):
Press and hold the "CLOCK" button for 3 seconds to advance the current time 1 hour, +1h
icon should appear on the display. Press and hold the clock button again to decrease the
time by 1 hour and the +1h icon will disappear. Refer to Diagram H
Diagram H
Clock
Power Back Up Feature:
In the event of a power failure, the timer will retain its settings for an estimated 3 months
assuming the power back up is fully charged.
HOUR
+
MIN
End of Countdown ON
CLOCK
Show Current Time
15042
15089
15079
Manual Version 2
11-24-2009
www.jascoproducts.com
loading

Summary of Contents for GE 15042

  • Page 1 See GE Timers and manuals http://waterheatertimer.org/GE-timers-and-manuals.html Programming the Countdown Feature: Digital Timer 1. Press the “SET” button repeatedly until the CTD icon appears on the display. This will appear after the ON/OFF program; refer to Diagram E 2. Press the “HOUR”, “MIN” buttons to set the amount of time desired for the device to be Install Set Up: on before turning off. 3. Press the “CLOCK” button to store the setting and return to the main display. 1. If the time screen is completely blank it will need to be plugged into an outlet before programming can begin. If the screen is displaying numbers, it can be programmed Diagram E and plugged into the wall afterwards. 2. Before programming, all settings should be reset. The reset button is located just below the “HOUR” button and is identified by ”RESET”. Use a paper clip or ball point pen to push the ”RESET” button. Once pushed the screen will show the display below on the screen. See Diagram A Diagram A After few seconds Activating the Countdown Feature: 1. Press the “HOUR” and “MIN” button simultaneously to activate the countdown feature.
  • Page 2 ícono +1h. Consulte el diagrama H. que se ve en el Diagrama D, sin tener que desplazarse por todas las horas. Diagrama H Diagrama D visualización de la hora actual Clock Función de reserva de energía: Cambio de modo: En caso de fallo del suministro eléctrico, el temporizador mantendrá sus configuraciones El modo actual aparece en la pantalla como: “ON”, “AUTO ON”, “OFF” o “AUTO OFF”, junto durante un periodo estimado de 3 meses suponiendo que la reserva de energía esté con la hora del día. Utilice el botón “MANUAL” para ajustar en la configuración deseada. totalmente cargada. Esto se puede utilizar para anular el temporizador, como se explica en la sección “Opción 15042 de anulación manual”. 15089 15079 Opción de anulación manual: Versión del manual 2 Independientemente de la programación, es posible en cualquier momento dado avanzar 11-24-2009 al siguiente comando de cambio presionando continuamente el botón “MANUAL”, como www.jascoproducts.com...

This manual is also suitable for: