Summary of Contents for Hitachi N 3804AB3

  • Page 1 Instruction and safety manual N 3804AB3 Model Stapler DANGER Improper use of this Stapler can result in death or serious injury! This Manual contains important information about product safety. Read and understand this Manual before operating the Stapler. Keep this Manual available for others before they use the Stapler.
  • Page 2: Table Of Contents

    BEFORE OPERATION ..........9 DEFINITIONS OF SIGNAL WORDS ......3 WORKING ENVIRONMENT ....... 9 EXPLANATION OF THE NAILING ACTION OF THE AIR SUPPLY ............9 HITACHI NAILER ..........3 LUBRICATION ..........10 COLD WEATHER CARE ........10 SAFETY TESTING THE STAPLER ........10 IMPORTANT SAFETY INSTRUCTIONS ADJUSTING AIR PRESSURE ......
  • Page 3: Important Safety Information

    NOTE emphasizes essential information. EXPLANATION OF THE NAILING ACTION OF THE HITACHI NAILER SINGLE ACTUATION MECHANISM (SINGLE SEQUENTIAL ACTUATION MECHANISM): First, press the push lever against the wood; next, pull the trigger to drive the fastener.
  • Page 4: Safety

    SAFETY IMPORTANT SAFETY INSTRUCTIONS FOR USING STAPLERS READ ALL INSTRUCTIONS DANGER OPERATORS AND OTHERS IN WORK AREA MUST NEVER USE OXYGEN OR OTHER BOTTLED WEAR SAFETY GLASSES WITH SIDE SHIELDS. GASES. EXPLOSION MAY OCCUR. When operating the Stapler, always Never use oxygen, combustible gases wear safety glasses with side shields, or any other bottled gases as a power source for the Stapler.
  • Page 5 Never place your face, hands or feet closer than 8 for repairs by a Hitachi authorized service center. inches (200 mm) from the firing head. 27. DO NOT DISCONNECT AIR HOSE FROM STAPLER A serious injury can result if the fasteners are WITH FINGER ON TRIGGER.
  • Page 6: Employer's Responsibilities

    The Stapler should never be left unattended since and resulting injuries. Only service personnel trained by Hitachi, people who are not familiar with the Stapler might handle it and injure the themselves.
  • Page 7: Operation

    OPERATION NOTE: The information contained in this Manual is designed to assist you in the safe operation of the Stapler. Some illustrations in this Manual may show details or attachments that differ from those on your own Stapler. NAME OF PARTS Stapling operation switching device Enlarged view of the valve part Switching...
  • Page 8: Specifications

    (.73 ltr/cycle at 7 kgf/cm STAPLE SELECTION WARNING ● Be sure to use only the genuine HITACHI staples for the N3804AB3. The use of any other staples can result in tool malfunction and/or staple breakdown, leading to serious injuries. Only staples shown in the Table below can be driven with this Stapler.
  • Page 9: Optional Accessories

    Stapler and extend the Stapler Accessories are subject to change without any life. These units should always be used. obligation on the part of HITACHI. Filter ....The filter removes moisture and dirt mixed in compressed air.
  • Page 10: Lubrication

    Keep the lubricator filled with Hitachi pneumatic tool lubricant. If a lubricator is not available, supply 5 – 10 drops of Hitachi pneumatic tool lubricant into the air plug on the Stapler twice a day. COLD WEATHER CARE Do not store the Stapler in a cold weather THE PUSH LEVER AND TRIGGER MUST environment.
  • Page 11 (2) Adjust the air pressure to 70 psi (4.9 bar 5 kgf/ Connect the air hose. Do not load any staples in the Stapler. Set the switching device to the upward position (SINGLE ACTUATION MECHANISM). (Set the switching device to the upward position completely as shown in the diagram.
  • Page 12: Adjusting Air Pressure

    (7) If no abnormal operation is observed, you may load staples in the Stapler. Drive staples into the workpiece that is the same type to be used in the actual application. THE STAPLER MUST OPERATE PROPERLY. ADJUSTING AIR PRESSURE WARNING Magazine Staple (3) Pull the staple feeder backward slightly, and press...
  • Page 13: Methods Of Operation

    (i.e. Set to SINGLE handing it to another person. ACTUATION MECHANISM.) To avoid double firing or accidental This Hitachi stapler is equipped with a stapler operation firing due to recoil. switching device. Set the switching device to SINGLE Use SINGLE ACTUATION MECHANISM or CONTACT ACTUATION MECHANISM.
  • Page 14 2 Pull the trigger with the Stapler off the Otherwise, it will be set to CONTACT workpiece. ACTUATION MECHANISM.) 3 Depress the push lever against the workpiece 2 Position the staple outlet on the workpiece to drive a staple. with finger off the trigger. 4 Move the Stapler along the workpiece with a 3 Depress the push lever firmly until it is bouncing motion.
  • Page 15: Adjusting The Stapling Depth

    After stapling: disconnect air hose from the Stapler; remove all staples from the Stapler; supply 5 – 10 drops of Hitachi pneumatic tool lubricant into the air plug on the Stapler; and open the petcock on the air compressor tank to drain any moisture.
  • Page 16: Changing The Exhaust Direction

    The nose cap is attached to the push lever tip to protect CHANGING THE EXHAUST DIRECTION the workpiece from scratches or damage. Remove in the order shown below when not using. 1 DISCONNECT AIR HOSE FROM STAPLER. WARNING 2 Pull out the nose cap in the direction of the arrow When changing the exhaust direction, as shown in the diagram.
  • Page 17: Service And Repairs

    5 Close guide plate and latch. recommended by Hitachi for repair. 6 In case of frequent jam, contact a Hitachi authorized service center. All quality Staplers will eventually require servicing or Storing replacement of parts because of wear from normal use.
  • Page 18 Open petcock on air compressor properly. tank. Operator troubleshooting Most minor problems can be resolved quickly and easily using the table below. If problems persist, contact a Hitachi authorized service center for assistance. PROBLEM CHECK METHOD CORRECTION Stapler operates but no staple is Check for a jam.
  • Page 21 NOSE CAP TRIGGER ARM (C) ROLL PIN D2.5 × 16 ROLL PIN D3 × 25 O-RING (1AP-10) PLUNGER SPRING O-RING (I. D. 1.8) PLUNGER VALVE BUSHING (A) RETAINING RING (E-TYPE) FOR D3 SHAFT ROLL PIN D3 × 32 HITACHI LABEL...
  • Page 24 Hitachi Koki Co., Ltd. Shinagawa Intercity Tower A, 15-1, Konan 2-chome, Minato-ku, Tokyo 108-6020, Japan Code No. C99156111 Printed in Taiwan...